Loading...
HomeMy WebLinkAboutPlanning Comm Reports/1984/03/14 AGENDA City Planning Commission Chula Vista, California Wednesday, March 14, 1984 - 7:00 p.m. City Council Chambers PLEDGE OF ALLEGIANCE - SILENT PRAYER ORAL COMMUNICATIONS 1. PUBLIC HEARING: Consideration of revised development plan for lots 324 and 325 of Hidden Vista Village (Windjammer Condos), PCM-80-13-B, Financial Scene, Inc. 2. PUBLIC HEARING: Consideration of tentative subdivision map for Appel Subdivision, Chula Vista Tract 84-3, Appel Development Corporation 3. PUBLIC HEARING: Consideration of tentative subdivision map for Le Trianon, Chula Vista Tract 84-4, The Wiechers Corporation DIRECTOR'S REPORT COMMISSION COMMENTS ADJOURNMENT AT to the Regular Business Meeting of March 28, 1984 at 7:00 p.m. in the Council Chambers TO: City Planning Commission FROM: George Krempl, Director of Planning SUBJECT: Staff report on agenda items for Planning Commission Meeting of March 14, 1984 1. PUBLIC HEARING: PCM-80-13-B Consideration of revised development ~lan for lots 324 and 325 of Hidden Vista Village (blindjammer Condos) - Financial Scene, Inc. A. BACKGROUND This item involves consideration of a revised plan for the development of lots 324 and 325 of the Hidden Vista Village Subdivision with a lO0-unit condominium project to be known as The Windjammer. The proposed project is located at the northwest quadrant of East "H" Street and Hidden Vista Drive within the Rice Canyon Sectional Planning Area of the E1 Rancho del Rey Specific Plan. The Environmental Impact Report, EIR-79-8, for the Hidden Vista Village development was previously certified by the Planning Commission and City Council. On February 2, 1984, the Environmental Review Coordinator found that the information contained in EIR-79-8 was adequate for the proposed project and satisfied CEQA review requirements and recommended that the Planning Commission recertify the EIR, noting that they will consider the information in the report as they reach a decision on the project. B. RECOMMENDATION 1. Recertify EIR-79-8 with the notation that the information in the report was considered. 2. Adopt a motion recommending that the City Coucil adopt a resolution approving the revised development plan for lots 324 and 325 of the Hidden Vista Village subdivision subject to the following conditions: a. An adjustment plat shall be processed to change the line between lots 324 and 325. Although not required, subsequent to recordation of new deeds corresponding to the adjusted lines we recommend that a record of survey be filed so that monuments can be placed in the field at the new lot corners. b. All easements for sewer and access granted to the City on Map 10051 shall be vacated if they no longer correspond to alignment of the private road (Fossil Circle). c. A new grading permit is required and the existing grading, landscape and irrigation plans revised. City Planning Commission Agenda Items for the Meeting of March 14, 1984 Page 2 d. Improvement plans shall require revision reflecting sewer, drainage and other facility changes. e. New sewer and access easements shall be granted to the City. f. Final site plan and architectural details shall be subject to Zoning Adminstrator approval upon application for building permits. C. DISCUSSION Approved SPA Plan In 1980, the City Council approved the Sectional Planning Area (SPA) Plan for the Rice Canyon area of the E1 Rancho del Rey Specific Plan as well as the tentative map for the Hidden Vista Village subdivision encompassing the entire SPA area. Also, approved at that time was the development proposal for lots 324 and 325 (approximately 9.3 acres) with a 102-unit condominium project. The development proposal consisted of a combination of four-plexes, six-plexes, and eight-plexes. Approximately two-thirds of the units were to be three-bedroom units with remaining one-third two-bedroom units. The units were to be served by a private loop street with access from Hidden Vista Drive. The buildings on the periphery of the property were three-story split-level units and the interior structures two-stories in height. The buildings within the interior were served by private cul-de-sac streets. All the units on the periphery were to have a one-car garage and one open parking space. The interior units were to have a two-car garage. The guest parking was to be located within parking bays located on the inside of the loop street. The architectural styling of the buildings was of contemporary design with stucco exteriors, wood trim and balconies, and either shake shingle or mission tile roofs. Revised Development Plan The applicant has submitted a revised plan for the development of the two lots which will contain 100 units instead of the 102 units as originally proposed. The reduction is partially due to the change in the basic structure type. The revised plan consists of 28 duplexes and ll four-plexes to be developed in two phases. City Planning Commission Agenda Items for the Meeting of l~arch 14, 1984 Page 3 The following is a breakdown of the proposed project: 1. There will be four basic floor plans: Unit 8~R Size Number Stories Parkin9 1 2 960 S.F. l0 1 1 or 2 car garage ** 2 2 ll6 S.F. 36 2* 1 or 2 car garage ** 3 3 1380 S.F. 28 2* 2 car garage 4 3 1484 S.F. 26 2* 2 car garage * Townhouse ** Plus one assigned open space for one-car garage units of which there will be a total of 15 one-car garages. 2. Phasing Phase I Phase II (Lot 324) (Lot 3851 Total Duplexes 12 16 28 Four-plexes 7 4 ll Unit 1 6 4 l0 Unit 2 20 16 36 Unit 3 14 14 28 Unit 4 12 14 26 Total Units 52 48 100 3. Parking Spaces Phase I Phase II Total Two-car garage 84 {42 garages) 86 (43 garages) 170 (85 garages) One-car garage l0 5 15 Assigned open space l0 5 15 Guest parking 30 12 42 Total 134 108 242 Note:Required parking per R-3 regulations - 212 spaces Assigned parking ratio: 2 to 1 City Planning Commission Agenda Items for the Meeting of March 14, 1984 Page 4 4. Miscellaneous a. There will be a swimming pool (Phase I) and a restroom/storage building in the center of the project. b. Perimeter fencing will be a 4-foot high fabric/wire mesh (black) with wood supports and railings. c. Each unit will have a private patio area defined by a 3-1/2 foot high wall. 5. Architecture The architecture of the proposed buildings is of contemporary design with a combination of stucco and wood siding exteriors, shake shingle roofs and wood trim and garage doors. Colors will be earth tones, light brown, beige and grey. D. ANALYSIS The applicant has indicated that the revised plan is necessary to meet present market demands in that the buyers are seeking more individual privacy which is better accomplished by the duplex and four-plex concept rather than the four, six, and eight unit structures as originally proposed. The change in structure type has resulted in the loss of two units in order to achieve a desired separation between structures {approximately l0 feet minimum} and a minimum setback of 22 feet from the private street to the face of the garage (all straight-in garages). Another significant change is the elimination of the three-story split level structures along the periphery of the project to two-story townhouse units. Since the first floor of these units is level, the grading concept will be changed slightly. The developer has been able to move the structures back further from the top of slope which extends down to the adjoining streets. This should result in a softer and less bulky appearance of the project from the street. The project meets all of the condominium requirements relating to private storage (end unit has a garage), private open space (patios} and parking. In fact, the parking of two spaces per unit exceeds present requirements. The 42 guest parking spaces should be adequate. City Planning Commission Agenda Items for the Meeting of March 14, 1984 Page 5 E. CONCLUSION Except for a reductior~ in the total number of units from 102 to 100 units, the revised development plan is similar to the original proposal with respect to circulation and architectural styling. The revised plan, however, will not be as massive in appearance due to the elimination of the three-story buildings on the periphery, a greater setback from the top of slope and the change in structure type to duplexes and four-plexes instead of the larger structures as originally proposed. It is, therefore, appropriate to recommend approval of the revised plan. WPC 0808P City Planning Commission Agenda Items for meeting of March 14, 1984 Page 6 2. PUBLIC HEARING: PCS-84-3 - Consideration of tentative subdivision map for Appel Subdivision - Chula Vista Tract 84-3 - Appel Development Corporation A. BACKGROUND 1. The applicant has submitted a tentative subdivision map known as Appel Subdivision, Chula Vista Tract 84-3, in order to develop a one lot condominium project consisting of 44 units on a 1.51 acre parcel located between the 500 block of Casselman and "D" Streets, 200 feet east of Broadway in the R-3 zone. 2. An Initial Study, IS-83-26, of possible adverse environmental impacts of the project was conducted by the Environmental Review Coordinator on June 2, 1983. The Environmental Review Coordinator concluded that there would be no significant environmental effects and recommended adoption of the Negative Declaration. B. RECOMMENDATION 1. Find that this project will have no significant environmental impacts and adopt the Negative Declaration issued on IS-83-26. 2. Based on the findings contained in Section "E" of this report, adopt a motion recommending that the City Council approve the tentative subdivision map for Appel Subdivision, Chula Vista Tract 84-3, subject to the following condition: a. The developer shall obtain a construction permit prior to approval of the final map for following work which shall be completed within one year from the date the permit issued: 1) Removal of the existing driveway on Casselman Street and replacement with curb and gutter. 2) Removal and replacement of broken sidewalk along Casselman Street. 3) Construction of driveway approaches on "D" Street and Casselman Street. 4) Construction of two type "A" outlets per Regional Standard Drawing D-25 on Casselman and "D" Streets. 5) Installation of two lO0-watt HPS street lights; one on Casselman Street and one on "D" Street. City Planning Commission Agenda Items for meeting of March 14, 1984 Page 7 C. DISCUSSION 1. Adjacent zoning and land use. North R-3 Apartments and single family dwellings South C-T & R-3 Commercial and apartments East R-3 Apartments West R-3 Apartments 2. Existing site characteristics. The subject property is a level and vacant 1.5 acre rectangular through lot (frontage on two streets) located between Casselman and "D" Streets (500 block) and 200 feet east of Broadway. The property has 251 feet of frontage along both streets and a distance between streets of 262 feet. Both streets are fully improved with curbs, gutters, sidewalks, and street paving. Some of the sidewalk is broken and needs replacing. Casselman Street has a 60 foot wide right-of-way with a 36 foot traveled, 6 foot wide parkway and 5 foot sidewalk. The right-of-way of "D" Street is 80 feet wide with a 40 foot traveled way, a 13 foot parkway and 5 foot sidewalk. The property line is located 12 feet back from the face of curb on Casselman Street and 20 feet on "D" Street. 3. Proposed development. The proposed development consists of 44 two-bedroom units in six two-story buildings. There will be five eight-unit structures and one four-plex. All of the units will have the required private open space in the form of patios or balconies. The private storage requirement will be located adjacent to the private open space. Parking for 74 cars will be provided on-site, 44 of which will be carports located on the east and west sides of the property. There will be 7 compact spaces and 1 handicap space. Access will be provided by two driveways on each street. There will be no through traffic from each street except for emergency vehicles. Other amenities include a laundry room and jacuzzi. Architecturally, the buildings will be contemporary Spanish design with mission tile roofs, stucco exteriors and stucco pop-outs around the windows. The project was approved by the Design Review Committee on December 15, 1983. In addition, building permits have been issued on the project and construction has begun. 4. Tentative map. The tentative subdivision map is for the sole purpose of selling the units as condominiums. The development meets all of the condominium requirements of the Code regarding storage, parking, and private open space and has been approved by the Design Review Committee. City Planning Commission Agenda Items for meeting of March 14, 1984 Page 8 D. FINDINGS Pursuant to Section 66473.5 of the Subdivision Map Act, the tentative subdivision map for Appel Subdivision, Chula Vista Tract 84-3, is found to be in conformance with the various elements of the City's General Plan based on the following: 1. The site is physically suitable for the residential development and the proposal conforms to all standards established by the City for such projects. 2. The design of the subdivision will not affect the existing improvements -- streets, sewers, etc. -- which have been designed to avoid any serious problems. 3. The project is in substantial conformance with the Chula Vista General Plan Elements as follows: a. Land Use - The proposed development is in keeping wi th the land use designation of high density residential at 13 to 26 DU's/acre. b. Circulation - The project will be served by existing streets and no streets are required across the site. c. Housing - The project will provide additional housing and home ownership opportunity for the residents of the community. d. Conservation - The site is located within the urbanized area of the City and there are no significant animal or plant species on the property. e. Park and Recreation, Open Space - The developer is required to pay a fee in lieu of dedicating and improving parks. f. Seismic Safety - The property is not near any known earthquake faults. g. Safety - The site is well within the response time of the fire station located on "F" Street. h. Noise - The units meet the requirements of the U.B.C. i. Scenic Highway - The site is not adjacent to a designated scenic route. j. Bicycle Routes - The adjacent streets are not designated bike routes but will accommodate bike traffic. k. Public Buildings No public buildings are proposed on the subject property. City Planning Commission Agenda Items for meeting of March 14, 1984 Page 9 4. Pursuant to Section 66412.2 of the Subdivision Map Act, the Commission certifies that it has considered the effect of this approval on the housing needs of the region and has balanced those needs against the public service needs of the residents of the City and the available fiscal and environmental resources. WPC 078gP/OO14Z negative declaration PROJECT NAME: Casselman Condominiums PROJECT LOCATION: 1.5 acre vacant parcel west of 560 Casselman Street PROJECT APPLICANT: Appel Development Corporation 5797 Chesapeake Court, Suite I San Diego, CA CASE NO: IS-83-26 DATE: June 3, 1983 A. Project Settin9 The project site consists of 1.5 acres of relatively flat vacant property with approximately 251 feet of frontage on both Casselman Street and "D" Street. Adjacent land uses consist of multiple family units on the east and west sides of the project, multiple family units across "D" Street to the south and multiple and single family units across Casselman Street to the north. There are no endangered plant or animal species located on or near the project site and no geologic hazards are known to exist in the project vicinity. B. Project Description The proposed project consists of the construction of 45 residential condominiums with a total of 75 on-site parking spaces. C. Compatibilit~ with Zonin9 and ~lans The proposed project will result in a net density of 29.74 units per acre which is consistent with current R-3 zoning and "high density residential" land use designation of the General Plan. D. Identification of Environmental Effects/Mitigation The following environmental effect can be mitigated to a level of insignificance through standard development requirements: Schools - The present enrollment levels at Feaster Elementary School and ~F~-]~---Vista Junior High School serving the project area, are above capacity. Implementation of the proposed project may result in the need for additional classroom space. A letter from each school district, indicating the adequacy of school facilities shall be required prior to the issuance of any permits for additional dwelling units. city of chula vista planning department environmental review section E. Findings of Insignificant Impact 1. The site is void of any significant natural or manmade resources and there are no geological hazards on or near the project site. Standard development requirements will reduce impacts to a level of insignificance. 2. The residential proposal is consistent with the General Plan and associated elements and is not anticipated to achieve short term to the disadvantage of long term environmental goals. 3. No impacts are anticipated to occur which could interact to create a substantial cumulative effect on the environment. 4. The project will not cause the emission of any harmful substance or noise which could prove detrimental to the health and welfare of human beings. G. Consultation 1. Individuals and Organizations City of Chula Vista: ~Steve Griffin, Associate Planner Roger Daoust, Senior Civil Engineer Ted Monsell, Fire Marshall Tom Dyke, Building Inspector Duane Bazzel, Assistant Planner Applicant's Designer: Kevin Knox 2. Documents IS-82-32, Bergh Condominiums WPC 0357P EN 6 (Rev. 12/82) The Initial Study application and evaluation forms documenting the findings of no significant impact are on file and available for public review at the Chula Vista Planning Department, 276 Fourth Avenue, Chula Vista, CA 92010. £NVI RO~lg[ R£VI£W COORDI~AIOR city of chula vista planning department e~vtronmental review section EN 6 (Rev. 12/82) STRE VALE CT. ' I ~, , I I ~ MC INTOSH '' ~ ST. ST. I I I I ~ I'r~ I M~'i MF I "D" Street I MF IiMF :l i~l I , SF i i i I 1 ~ ' I I -* [,, , '' ,, ~, I II I I I · I I I I ~ I I I '1 ~ FLOWER I I ~NORTH City Planning Commission Agenda Items for Meeting of March 14, 1984 Page 10 3. PUBLIC HEARING Consideration of tentative subdivision map for Le Trianon Chula Vista Tract 84-4 - The Wiechers Corporation A. BACKGROUND 1. The applicant has submitted a tentative subdivision map known as Le Trianon, Chula Vista Tract 84-4 in order to develop a one lot condominium project containing nine units on a 14,500 sq. ft. parcel located at 330 "G" Street in the R-3 zone. 2. An Initial Study, IS-81-50, of possible adverse environmental impacts of the project was conducted by the Environmental Review Coordinator in February 1983. The Environmental Review Coordinator concluded that there would be no significant environmental effects and recommended adoption of the Negative Declaration. B. RECOMMENDATION 1. Find that this project will have no significant environmental impacts and adopt the Negative Declaration issued on IS-81-50. 2. Based on the findings contained in Section "E" of this report, adopt a motion recommending that the City Council approve the tentative subdivision map for Le Trianon, Chula Vista Tract 84-4, subject to the following conditions: a. The developer shall remove and reconstruct the sidewall, curb and gutter along the entire frontage of the subject property. b. The developer shall construct a driveway approach per Chula Vista standards. C. DISCUSSION 1. Adjacent zoning and land use. North R-3 Apartments and duplexes South R-3 Apartments East R-3 Apartments (15 units) West R-3 Apartments (14 units) 2. Existing site characteristics. The subject property is a 50' x 290' level parcel located in the south side of "G" Street between Third and Fourth Avenues. The site was formerly developed with an older single family dwelling. However, the nine-unit project is presently under construction. City Planning Commission Agenda Items for Meeting of March 14, 1984 Page 11 3. Proposed development. The development will be a 9-unit condominium project consisting of 3 two-story residential structures connected by carports. Each residential structure will have three units; one single bedroom unit at ground level and 2 two-bedroom units above. The upper units will project over the access driveway located on the east side of the site. There will be 15 off-street parking spaces; lO spaces in carports and 5 open spaces located at the rear of the property. One guest space is provided at the curb. The project meets the condominium requirements regarding parking, private open space and private storage. The lower units will have patios (62 sq. ft.) and the upper units will have 6'xlO' balconies. The roof of the carports is also designed to be used for open space. The storage for the lower units will be located under the stairs and upper units will have attic storage with access provided by pull-down stairs. The buildings are of contemporary architectural design with a stucco exterior, composition roof shingles and wood trim. The project was reviewed and approved by the Design Review Committee in August 1983. D. FINDINGS Pursuant to Section 66473.5 of the Subdivision Map Act, the tentative subdivision map for Le Trianon, Chula Vista Tract 84-4, is found to be in conformance with the various elements of the City's General Plan based on the following: 1. The site is physically suitable for the residential development and the proposal conforms to all standards established by the City for such projects. 2. The design of the subdivision will not affect the existing improvements -- streets, sewers, etc. -- which have been designed to avoid any serious problems. 3. The project is in substantial conformance with the Chula Vista General Plan Elements as follows: a. Land Use - The sale of multiple family units as condominiums does not affect the Land Use Element. b. Circulation - The project is served by an existing street. c. Housing - The conversion will increase the City's housing stock and will provide additional opportunity for home ownership. d. Conservation - The property has been previously developed with a home of no historic significance. City Planning Commission Agenda Items for Meeting of March 14, 1984 Page 12 e. Park and Recreation, Open Space - The developer is required to pay a fee in lieu of dedicating and improving parks. f. Seismic Safety - The property is not near any known earthquake faults. g. Safety - The site is well within the response time of the fire station located on "F" Street. h. Noise - The units are designed to meet the requirements of the U.B.C. regarding noise attenuation. i. Scenic Highway - The site is not adjacent to a designated scenic route. j. Bicycle Routes - "G" Street is not a designated bike route. k. Public Buildings No public buildings are designated on the site. 4. Pursuant to Section 66412.2 of the Subdivision Map Act, the Commission certifies that it has considered the effect of this approval on the housing needs of the region and has balanced those needs against the public service needs of the residents of the City and the available fiscal and environmental resources. WPC 0779P/OO14Z ADDENDUM A TO NEGATIVE DECLARATION IS-81-50 FINDINGS REGARDING THE ADEQUACY OF CONDITIONED NEGATIVE DECLARATION IS-81-50 A. BACKGROUND The environmental review procedures of the City of Chula Vista provide that the Environmental Review Coordinator shall review any significant project revisions to ensure that there will be no potential or significant environmental impacts which have not been previously evaluated in a negative declaration or environ- mental impact report. If the ERC finds that a proposed project is essentially the same in terms of impact or circumstances under which the project is to be undertaken, the ERC may recommend that a previously prepared ND/IS or EIR be utilized as an environmental document for the project. B. PROJECT DESCRIPTION The project applicant proposes to construct a nine-unit apartment/condominium project which will include a total of 15 on-site parking places, l0 of which will be carport spaces. Two previous projects have been proposed on the project site at 330 "G" Street; (1) an eight-unit condominium and (2) a twelve- unit senior citizen project. The zoning ordinance will allow a maximum of nine multiple-family units on this site. C. ANALYSIS 1. Soils. Expansive soils have been found to be present in the project area and a soils report was previously required of the project. There are no changes in the project that would change this requirement or further exacerbate the expansive soils problem. 2. Drainage. The proposed development, as well as the previous proposals, will result in a minor increase in drainage. The difference in runoff between the projects would be indistinguishable. As was previously noted, there is a potential for impact on downstream storm drain facilities due to cumu- lative development within this drainage basin. 3. Parks. As was noted in the previously prepared Negative Declaration, the park area in this project's park district is currently insufficient, however, a population increase generated by either project would not result in a significant impact on the ability to provide park and recreational services. The project, as currently proposed, would result in an increased population estimate from 16 people to 18 people, or a slight increase in the need for park facilities from .032 acres to .036 acres. Mitigation will remain the same. 4. Schools. The proposed nine-unit project will have essentially the same effect on local educational facilities as the previous eight-unit proposal. No additional mitigation will be required. D. CONCLUSIONS Based on the above discussion, I hereby find that the proposed nine-unit apartment/condominium project is essentially the same in terms of environmental impact or circumstances under which it is being undertaken and recommend that the Design Review Conmittee, Planning Co~ission and City Council adopt Negative Declaration IS-81-50 prior to taking action on the project, subject to the miti- gation measures specified in the Negative Declaration. Dougla~/D. Reid Environmental Review Coordinator negative deClaration PROJECT NAME: Guillemette Condominiums PROJECT LOCATION: 330 G Street PROJECT APPLICANT: Louis Guillemette 318 G St., Apt. 5 Chula Vista, Ca 92010 CASE NO: IS-81-50 DATE: June 25, 1981 A. Pro3ect Setting The project'involves approximately 0.33 acres of property which presently contains one single family dwelling at 330 G St. Adjacent land uses consist of multiple family dwellin~ to the west and east, a duplex and commercial parking lot to the south, and multiple family dwellings across G St. to the north. The project site is void of any significant wildlife and there are no significant natural or man-made resources present. Expansive soils may be present on the site and there are no known geologic hazards within the project vicinity. B. Pro3ect Description The applicant proposes to construct 8 condominium units contained in one two-story structure. Fifteen parking spaces are proposed in addition to appropriate landscaping and private open space. C. Compatibility with zoning and plans The proposed project is zoned R-3 (Multiple family) and would permit a maximum of 9 dwelling units. The project is compatible with the General Plan and all associated elements. D. Identification of environmental effects 1. Soils The City Engineering Dept. has indicated that expansive soils are present in the project area, therefore a soils report should be prepared and recommendations incorporated into the project to ensure stable construction. city of chula vista planning department environmental review section IS-81-50 2 2. Drainage The increase in the amount of surface runoff which empties into existing storm drain systems resulting from this project will be insignificant. It should be noted that future cumulative development within this drainage basin will warrant increasing the capacity of existing downstream storm drain facilities. 3. Parks The existing park acreage in Park Dist. No. 3 is 8 6 acres, and the current requirement for this district is 22.4 acres. The proposed project will generate the need for .03 acres of parkland which can be satisfied by payment of in-lieu park fees which will be used for the acquisition and development of additional park acreage. 4. Schools The local elementary and junior high schools serving the project area are'currently approaching capacity enrollment. This project, combined with proposed projects in the same vicinity will serve to increase enrollment to maximum capacity levels. The developer shall comply with public facilities policies and ensure adequate classroom space for new students. E. Mitigation necessary to avoid significant effects 1. The developer shall not oppose the formation of any assessment district formed for the purpose of providing adequate storm drainage facilities to serve the project area. (The following measures are standard development regulations and are advisory only) 2. A soils report shall be prepared and all recommendation are to be incorporated into the project. 3. The developer shall provide the city with written assuraDce from the school districts that adequate educational facilities are available for all new students. IS-81-50 3 4. Park acquisition and development fees shall be paid in-lieu of parkland dedication prior to subdivision and development of the property. F. Findings of insignificant impact 1. The site is void of any natural or man-made resources, and there are no geologic hazards present on the site. Expansive soils may be present on-site, however, proposed mitigation will ensure stable construction. 2. The proposed residential development is consistent with the General Plan and associated elements and is not anticipated to achieve short term to the disadvantage of long term environ- mental goals. 3. No impacts are anticipated to occur which could interact to create a substantial cumulative effect on the environment. 4. The project will not cause the emission of any harmful substance or noise which could prove hazardous to the health and welfare of human beings. G. Consultation 1. City of Chula Vista Steve Griffin, Assoc. Planner Roger Daoust, Senior Eng. Shabda Roy, Assoc. Eng. Tom Dyke, Plan Checker Ted Monsell, Fire Marshal Duane Bazzel, Asst. Planner Tom Hyde, Applicants designer 2. Documents IS-81-40 Darley Apts. The Initial Study Application and evaluation forms documenting the findings of no significant impact are on file and available for public hearing at the Chula Vista Planninq Dept. 276 4th Avenue, Chula Vista, CA 92010 ' ' ENVIR~ENTAL REVIEW COORDINATOR city of chula vista planning department ~--~ environmental review section EN 6 I~ I I I II Ii ~ Sho SF SF SF SF MF TF TF MF I' I ~ I ~ I MFI ~MF I I VANCE I SF I SFIIMF ISF MF IMF I ~ I '~ ~lih ROOSEVELT ST -~ ~-,-- -I ~ I I I ---