HomeMy WebLinkAboutPlanning Comm Reports/1982/05/26 AGENDA
City Planning Commission
Chula Vista, California
Wednesday, May 26, 1982 - 7:00 p.m. City Council Chambers
PLEDGE OF ALLEGIANCE - SILENT PRAYER
ORAL COMMUNICATIONS
1. PUBLIC HEARING: Conditional use permit PCC-82-16, request to establish
a residential care facility in the O0 block of Second Avenue
in the R-1 zone - Sue Hudson
DIRECTOR'S REPORT
COMMISSION COMMENTS
To: City Plannin'~-~ommission
From: Bud Gray, Director of Planning /~)~
Subject: Staff report on agenda items for Planning Commission
Meeting of May 26, 1982
1. PUJBkIC HEARING: Conditional use permit PCC-82-16; request to establish
a residential care faciIltJ/ In tree uu D)OCK Or 5econo
AVenue in the R-1 zone - Sue Hudson
A. BACKGROUND
1. The applicant filed and received approval for a tentative subdivision
map in 1979 to subdivide the subject property into nine single family lots.
2. The applicant is now requesting permission to establish a 105 unit
residential care facility for seniors (62 years of age and older) on a 2.1
acre site located on the east side of the O0 block of Second Avenue (directly
opposite of "C" Street), on the west side of the north end of Las Flores Drive
extended northerly from "D" Street in the R-1 zone.
3. An Initial Study, IS-82-28, of possible adverse environmental impacts
of the project was conducted by the Environmental Review Committee on
May 6, 1982. The Committee concluded that there would be no significant
environmental effects and recommended that a conditioned Negative Declaration
together wi th the fol 1 owl ng mi tigation measu res be adopted.
1. A new or amended soils and geologic report shall be prepared to
address the proposed project and all recommendations shall be
incorporated into the project.
2. Architectural review should be referred to the Design Review
Committee for a determination of the design compatibility within the
surrounding area.
3. Adequate fire protection shall be assured prior to approval of any
building permits.
4. The paved access on "D" Street between Las Flores Drive and Second
Avenue shall be widened to 24 feet.
5. Shrubs located within the sight distance triangle at the easterly
corners of "D" Street and Second Avenue shall be trimmed below 3 feet
in height (Municipal Code Chapter 12.12.120).
B. RECOMMENDATION
1. Find that this project will have no significant environmental impacts
and adopt the conditioned Negative Declaration issued on IS-82-28.
2. Adopt a motion to deny the request, based on the lack of compatibility
with the area as stated in the conclusion portion of the report.
City Planning Commissi~
Agenda Item for Meeting of May 26, 1982 page 2
C. DISCUSSION
1. Adjacent zoning and land use.
North AGR. KOA Campgrounds
South R-1 Vacant and single family dwellings
East R-1 Vacant
West R-1 Single family dwellings
2. Existing site characteristics.
a. The project site is essentially an "L" shaped parcel with 80
feet of street frontage on the east side of Second Avenue and 257 feet of
frontage on the proposed extension, of Las Flores Drive approximately 1,250
feet north of "D" Street. The majority of the property is located on the east
facing slope of a small canyon located between Second and Minot Avenues. A
portion of the property (below the elevation of 35 feet) lies within the 100
year flood level of the Sweetwater River Flood Plain. The property has an
average natural slope of 15% and a maximum slope of 60%. The site is vacant
except for some small wooden sheds and a few trees.
b. The applicant also owns a 92'Xl16' parcel adjacent to the
southwest corner of the project site which is not included in the proposed
development. The property has very steep slopes and a drainage inlet which
directs water onto the property that will require attention with the
development of the subject property.
3. Proposed use.
a. The proposed facility vrill consist of 105 units and one
manager's unit. There All he 47 one bedroom units (532 square feet each) and
58 studio units (285 square feet each). Each unit will have a 4'XlO' balcony
or patio. A central kitchen and dining room is proposed in lieu of individual
kitchens and will provide two servings three times a day, seven days a week.
A chapel, libra~, activity room, laundry, a drug store/gift shop, a
combination beauty/barber shop and a central patio area are proposed. Other
services will include maid service, social and recreational activities, and
tran sportati on.
b. There will be 22 full time staff employees, 5 part time
employees and a manager.
4. Proposed development.
a. Because of the topography the building will he stepped up from
Las Flores Drive. There will be five floor levels, but not mere than three
stories in height at any ground level. The third sto~ of the lower portion
of the building will be at the same level as the first floor of the upper
portion. The highest portion of the building will be at the same elevation as
Second Avenue. Because of the height, two elevators will be provided in
addition to exterior covered stairways.
City Planniag Commission
Agenda Item for Meeting of May 26, 1982 Page 3
b. Access to the facilities will be from both streets. There will
be 12 parking spaces located on Second Avenue, one of which will be reserved
for a company van. A pedestrian bridge will lead from the parking area to the
third floor of the upper level. There will also be 36 parking spaces adjacent
to Las Flores Drive, three of which will be located for company vehicles. The
total guest parking provided will be 44 spaces, a ratio of approximately one
space per 2.4 units.
5. Similar establishments.
There are two other similar establishments in the general vicinity,
located in R-3 zones. These are the Chula Vista Inn at ltl Fourth Avenue
which has 160 units and Fredricka Manor at 183 Third Avenue. Fredrtcka Manor
has both a high-rise full-care facility as well as single family dwellings as
part of the total complex.
6. Code requirements.
The proposed development meets the technical requirements of the
zoning ordinance as set forth in Section lg.58.110. The site contains more
than one acre and is located on a collector street (Second Avenue). The
buildings are located a minimum of 20 feet from all property lines. Because
of its height and type of residency an automatic fire extinguishing system
will be required. If the project is approved, other requirements governing
street improvements, drainage and so forth will have to be met before a
building permit is issued (See attached memo from the Engineering Division).
D. ANALYSIS
1. The applicant has submitted a well designed proposal which meets the
regulations of the code governing the use. The parking ratio of one space per
2.4 units is within the range normally expected for senior housing
developments. The transportation provided by the facility should reduce the
need for automobiles by the residents. In addition the closest public
transportation is approximately 3/8 of a mile away.
2. Even though the elevations are somewhat schematic it appears that the
architecture will be attractive. The stair-stepping of the building down the
slope reduces its overall impact and affords views for many of the proposed
units. The expected services would likely result in a self-contained
environment inducive to social interaction.
3. The biggest drawback to the proposal is one of compatibility with the
adjacent land uses. Except for the area to the north, the surrounding area is
zoned R-1 and is either developed with single family homes or anticipated to
be developed as such (two tentative subdivision maps have been approved for
single family homes on Las Flores Drive). The density of an R-1 area is
approximately 5 units per acre, whereas the density of the proposed project Is
approximately 50 units per acre excluding the 92'Xl16' area not included in
the project.
City Planning Commission
Agenda Item for Meeting of May 26, 1982 Page 4
E. CONCLUSION
It is my conclusion that the proposed use is incompatible with the single
family character of the area based on the following factors:
1. The proposed density is ten times greater than standard single family
developments.
2. The structure represents a significant departure from the existing and
proposed single family housing in the area, being more massive in appearance
and size.
3. Although the site is located on a collector street (Second Avenue),
75% of the required parking is located on Las Flores Drive and the number of
trips generated by the facility will exceed that normally generated by single
family homes.
I therefore recommend that the Planning Commission deny the request based on the
three factors listed above.
negative declaration
PROJECT NAME: Hudson Senior Housing Facility
PROJECT LOCATION: North and east of 9 Second Avenue
PROJECT APPLZCANT: Sue Hudson, a.k.a.
Royal Engineering and Development Corporation
54 Antigua Court
Corooado, CA 92118
CASE NO. IS-82-28 DATE: May 6, 1982
A. Project Setting
The project site consists of approximately 2.35 acres of vacant property
with an average natural slope of 21%, located north and east of 9 Second Avenue.
The project site has 80 feet of frontage on Second Avenue and 257 feet of frontage
on the future extension of Las Flores Drive. An elevation difference of approxi-
mately 60 feet exists from Second Avenue down to Las Flores Drive.
Adjacent to Second Avenue and approximately 8 feet below the level of the
street, is a relatively level pad. Below that point the topography drops off steeply
down to the flnnr of the Sweetwater River valley and existing pasture land.
The valley floor is located below the 100 year flood plain (elevation 35 feet)
and is subject to inundation.
A mature pepper tree and approximately two eucalyptus trees exist on the
project site. No known endangered wild life or plant species exist on the project
site. There are no known earthquake faults on or near the project.
B. Project Description
The project consists of the development of a 105 unit (47 one bedroom and
58 studios) residential home care facility for seniors 62 years of age and older.
The proposed building will have five floor levels, but will not exceed three levels
in height as measured from the ground. The facility will feature a central kitchen
and dining room as well as other activities, such as a chapel, drug and gift shop,
and barber/beauty shop. Parking 'for 48 cars on site will be provided with access
to 12 spaces from Second Avenue and access to 36 spaces from Las Flores Drive. In
addition, a pedestrian bridge will be provided from the upper lot to the main structure.
Las Flores Drive will be constructed in conjunction with the proposed development
from "D" Street to the northerly boundary of the project site.
C. Compatibility of zoning and plans
The proposed project is considered an "unclassified land use" in the zoning
ordinance and, therefore, requires approval of a conditional use permit by the
Planning Commission. The project is compatible with the goals and objectives of the
General Plan and its associated elements.
city of chula vista planning department
environmental review ~.ectlon
IS-82-28
Page 2
D. Identification of environmental effects
1. Geologs/Soils
The nearest major earthquake fault to the project site is the north/south
trending Sweetwater Fault, which is located approximately 1,000 feet east of the
slte. Special report 123 by the State of California Division of Mines and Geology
identifies the presence of a potential northeast/southwest trending fault through
photographic evidence located approximately 200 feet northeast of the project site.
A soils and geologic investigation for the project site was prepared in
February, 1979 (Geocon, Inc.). The report indicated the presence of expansive
soils and the potetntial for liquefaction occurring on the site. A new or amended
soils and geologic investiation should be prepared to address the proposed project.
Recommendations of the report should be incorporated into the project to mitigate
potential impacts. No substantial problems are anticipated.
2. Ground Water
The soils and geologic investigation (Geocon, Inc.) identifies the presence
of ground water approximately 7 feet beneath the existing surface at the easterly
end of the property. No excavation is proposed at this end of the property, in fact,
this area will be subject to fill. The report indicates that if surface drainage
on the site is directed into contained drainage structures, the potential for future
ground water or ground water/seepage related problems should be minimal.
3. Biolo~s
The construction of Las Flores Drive in conjunction with the proposed project
will have an impact on existing San Diego ragweed populations north of "D" Street.
These impacts were thoroughly discussed in EIR-78-1 (Hudson Valley Estates) along
with project alternatives. Construction of Las Flores Drive was found not to have
a significant effect on ragwood populations in the San Diego region.
A stand of mature eucalyptus trees presently exists on the property north
of the project site, with two trees located on the site. Proposed plans have
allowed for the preservation of all of these trees.
4. Drainage
A portion of the project site is located within the Sweetwater River lO0-
year flood plain (elevation 35 feet). The designer proposes filling the lower
half of the property to elevation 35.6 feet (residential floor levels all above
36 feet).
The applicant's engineer has submitted plans for the extension of Las Flores
Drive which includes drainage measures for each adjacent lot. The elevation of
Las Flores Drive will be such that vehicles can pass during a lO0-year flood. Drain-
age facilities are proposed within Las Flores Drive and will terminate with a
rip-rap energey dissipator system at the northern end of the project site and Las
Flores Drive. Existing drainage patterns will handle run-off from this point on to
the valley floor. The increased run-off due to the development of this project is very
minimal due in-part to the steep topography of the property. The total run-off when
the entire basin is developed is calculated to be about 107 cu. ft. per second (10 yr.
frequency).
IS-82-28
Page 3
5. Historical
A portion of the project site (upper pad adjacent to Second Avenue) was
once a portion of the right-of-way for the National City and Otay Railroad line
(NC&O Railway). The railway extended its lines through Chula Vista and Otay to
the Imperial Beach area in 1888. In 1908 modern electric cars replaced the
original steam engines when the San Diego Southern Railroad Company obtained
control of the NC&O Railway. The disastrous flood of 1916 "completely obliterated"
the railroad crossing in the Sweetwater flood plain and the result was abandonment
of portions of the track, including this site.
The Chula Vista Historical Sites Board examined the NC&O Railway right-of-
way in 1977 and did not recommend that the right-of-way be designated as an historical
site, based on the finding that topographical features which remain are not signif-
icant enough to be so designated. Since circumstances have not changed significantly
in five years, there are no remains existing on the project site. The project site
is not considered an active candidate as a historical site.
6. Aesthetics
The size of the proposed residential care facility does not appear to be
consistent with other single family residential structures in the Las Flores
Drive area. The question of aesthetics is largely a subjective one, therefore,
review of the architecture and compatibility of the structure will be handled by
the Planning Commission (conditional use permit), and should be referred to the
Design Review Committee.
7. Social
The residential care facility will amount to a gross density of approxi-
mately 44 dwelling units per acre. The General Plan designation for the area
amounts to a gross density of 12 dwelling units per acre, maximum. Since the
units provided are designed for senior citizens, they would involve a fewer
number of inhabitants than a conventional multiple family development. Additional
vehicular trips in the area of Las Flores Drive will result in nuisance traffic
and noise levels which do not presently exist in this area but will not reach
significant levels. The occasional presence of emergency vehicles and related
sirens would be considered an urban nuisance noise which would not occur on a
regular basis and cannot be considered a substantial environmental issue.
8. Fire Protection
The City Fire Marshal has indicated that difficulties may be experienced
in providing adequate fire protection to the proposed facility. Adequate fire
protection should be assured prior to building permit approval. This can be assured
through standard development regulations and is not a significant environmental issue.
9. Parks and Recreation
The proposed residential care facility will be located within Park District
2.01, which presently has no developed park acreage. The proposed facility does
provide an interior common passive courtyard area for residents of the complex and
transportation vans for transportation to senior citizen facilities located within
two miles of the site.
IS-82-28
Page 4
10. Transportation
Street access is presently unavailable to the lower project site. The
Engineering Department has indicated that "D" Street, from Las Flores Drive to
Second Avenue, will require widening to at least a 24 foot wide street width in
addition to the construction of [as Flores Drive north of "D" Street. A cul-de-sac
will be installed at the northern end of Las Flores Drive.
The Traffic EDgineer investigated the intersection of "D" Street
and Second Avenue in November, 1979 and found that the sight distance across both
corner parcels was acceptable, provided that modifications were made to plant
material heights (3 feet maximum). A field inspection made recently revealed
that shrubs on the northerly corner need to be cut down to provide adequate sight
distance.
E. Mitigation necessary to avoid significant impacts
1. A new or amended soils and geologic report shall be prepared to address the
proposed project and all recommendations shall be incorporated into the
project.
2. Architectural review should be referred to the Design Review Committee for
for a determination of the design compatibility within the surrounding area.
3. Adequate fire protection shall be assured prior to approval of any building
permits.
4. The paved access on "D" Street between Las Flores Drive and Second Avenue
shall be widened to 24 feet.
5. Shrubs located within the sight distance triangle at the easterly corners
of "D" Street and Second Avenue shall be trimmed below 3 feet in height
(Municipal Code Chapter 12.12.120).
F. Findings of insignificant impac__t
1. There are no significant natural or manmade resources within the project
area which could be adversely affected by the project implementation. There
are no known earthquake faults located on the project site.
2. Approval of a conditional use permit by the Planning Commission would assure
compatibility with the General Plan,
3. All potential impacts can be mitigated and none are anticipated to interact
and cause a cumulative effect on the environment.
4. The project will not create any source of significant noise or odors, nor
will any hazards to human beings result.
IS-82-28
Page 5
G. Consultation
1. Individuals and organizations
City of Chula Vista Steve Griffin, Associate Planner
Bill Harshman, Senior Engineer
Tom Dyke, Building Department
Ted Monsell, Fire Marshal
Duane Bazzel, Assistant Planner
Sue Hudson, applicant
2. Documents
EIR-78-1, Hudson Valley Estates
IS-79-58, Hudson Valley Estates No. 2
The Initial ~1 ~ ' ' ' '
-~, ~ ,: .'~";'] ~c~:~:~on .'~n~l ,~v.]luation forms documenting the
findin(:s of no s~,~ni ficant in:p,~ct ar~ on"~l_' o and available for
public review ,~t ~h,~ Chu[,~ t'][;ta ['lanninq Dept., 276 4th Avenue,
Chu[a Vista, CA 920[0.
ENVIRO~.blENTAL P~Vr~W COOF~INATOR
city of chula vista planning department ~
environmental review lection
April 8, 1982
File: HY029
TO: Ken Lee, Principal Planner ~\ j
FROM: Ken Goldkamp, Senior Civil Enginee~per '~
SUBJECT: Conditional Use Permit for Sue Hud ty (PCC-82-16)
We have no comments regarding the requested change in use of this property.
However, the applicant should be advised of our requirements at the time
of development.
Prior to the issuance of a building permit, the following requirements shall
be met:
1. A grading plan is to be prepared by a registered civil engineer and
approved by the City Engineer.
2. A grading permit is to be obtained by the owner in accordance with
ti~ City's Grading Ordinance No. 1797.
3. Proper certification by the private civil engineer and soil engineer
is to be submitted to this department.
4. Owner shall be responsible for obtaining 30 feet of street right-of-way
for Las Flores Drive from the south property line of the subject
parcel southerly to "D" Street.
5. Owner shall dedicate 38 feet along the easterly portion o? subject
property for Las Flores Drive right-of-way.
6. A letter of permission must be obtained from the adjacent property
owner to install a temporary cul-de-sac at the north end of Las Flores
Drive adjacent to the northerly property line of the subject property.
Prior to fra~in? or electrical inspection on the proposed building, the
owner is required to post the necessary bonds and obtain a construction
permit from this office for the follo~ing work;
1. Construction of public improvements along the subject property including
but not limited to: curb, gutter, sidewalk, A.C. paving to l0 ft. east
of the centerline of Las Flores Drive, and required street lights in
accordance with plans prepared by a registered civil engineer and apt~roved
by the City Engineer.
2. Install a minimum 24 ft. wide strip of A.C. pavement on Las Flores Drive
from the subject property south to "D" Street.
Ken Lee -2- April 8, 1982
3. Provide a minimum width of 24 ft. of A.C. pavement on "D" Street from
Las Flores Drive to Second Avenue.
4. Sidewalk is to be installed along the Second Avenue frontage of the
subject property and all abandoned driveway depressions are to be
replaced with standard curb.
5. A temporay cul-de-sac is to be installed at the north end of Las Flores
Drive adjacent to the northerly property line to include the following:
a. A.C. pavin§ with a minimum radius of 28 ft.
b. A.C. berm around the perimeter of the cul-de-sac.
If the applicant has any further questions regarding these requirements,
please have them contact John Hardesty, Permits Engineer, at 575-5040.
Jl~H:fpw
cc: Permits
I
I
I
I