HomeMy WebLinkAboutItem 3 - Staff report C H U L A VISTA
PLANNING
COMMISSION E
AGENDA STATEMENT
Item: 3
Meeting Date: 9/25/19
ITEM TITLE: Public Hearing: Consideration of Design Review (DR19-
0001)Approving a 143,000 square-foot Self-Storage Facility on a 2.81-acre
lot located at 1008 Industrial Avenue. The property is zoned General
Industrial Precise Plan (IP) with a General Plan Designation of Limited
Industrial (IL).
Resolution of the City of Chula Vista Planning Commission Approving
Design Review Permit DR19-0001 for a 143,000 square-foot Self-Storage
Facility on a 2.81-acre lot located at 1008 Industrial Avenue. The property
is zoned General Industrial Precise Plan (IP) with a General Plan
Designation of Industrial (IL).
Applicant: Wentworth Property Company, LLC.
SUBMITTED BY: Genevieve Hernandez, Associate Planner
REVIEWED BY: Kelly Broughton, Director of Development Services
INTRODUCTION
In accordance with the Chula Vista Municipal Code Wentworth Property Company, LLC
(Applicant) has submitted a Design Review application for approval of the Chula Vista Self-
Storage facility at 1008 Industrial Boulevard located west of the intersection of Industrial
Boulevard and Moss Street(the"Chula Vista Self-Storage Project" or"Project")that includes the
following:
• Architectural Plans
• Civil Engineering Plans
• Landscape Plans
• A Site Plan showing the building,parking lot and drive aisle locations, as well as vehicular
and pedestrian circulation and access
PROJECT DESCRIPTION
The Chula Vista Self-Storage Project is a multi-building self-storage facility consisting of three
Planning Commission
DR19-0001
September 25,2019
Page -2-
self-storage buildings with a combined 142,121 square-feet of self-storage space, comprised of(2)
one-story buildings with drive up units, and (1) three-story building with interior access to units.
A 1,488 square-foot office for leasing and management is also provided, that yields a total of
143,609 gross square-feet of development. The primary entrance is located off of Industrial
Boulevard. A secondary Fire Department exit/access gate is provided on the Southwest corner of
the site connecting to the adjacent property at 1002 Industrial Boulevard through an access
easement granted by the owners of the adjacent parcels.
The site is secured on all four side with building walls, new fencing, and existing fencing along
the I-5 off-ramp. Customers can access the facility through a secured gate. The drive-up buildings
will have direct access from the driveways and the new three-story building is accessed through a
secured lobby, using a key code. There are 25 parking spaces on site. Fourteen parking spaces are
provided adjacent to the three-story storage building(Building 3),five parking spaces are provided
at the southwest end of the site, and four parking spaces are provided near the rental office, located
outside the security gate. At completion of the Project, all the storage units in the three-story
building will be internally accessed and climate controlled.
The existing parking lot, asphalt and site light poles will be demolished to construct the Project.
The existing cell towers located on the northern portion of the site will remain in their current
locations, and cell companies will be given access to the site for maintenance.
ENVIRONMENTAL REVIEW
The Development Services Director has reviewed the Project for compliance with the California
Environmental Quality Act(CEQA) and has determined that the Project qualifies for a categorical
exemption pursuant to Section 15332 of the State CEQA Guidelines. Thus, no further
environmental review is required.
RECOMMENDATION
That the Planning Commission adopt Resolution DR19-0001, approving the Chula Vista Self-
Storage Project, based on the findings and subject to the conditions contained therein.
DISCUSSION
Project Site Characteristics
The Chula Vista Self-Storage Project is located at 1008 Industrial Boulevard. The 2.81-acre site is
located east of the 1-5 Freeway at the intersection of Industrial Boulevard and Moss Street. The
parcel is an existing parking lot adjacent to the prior Toys `R' Us site.
The following table identifies the General Plan, Land Use Designation and Existing Land Use for
the project site and adjacent properties:
Planning Commission
DR19-0001
September 25,2019
Page -3-
General Plan,Zoning Land Use Designations and Existing Land Uses
General Plan Zoning Designation Existing Land
Use
Proj ect Industrial General Industrial Parking Lot
Precise Plan(IP) (vacant site)
North Industrial Limited Industrial Industrial Shell
Precise Plan ILP
South Industrial General Industrial Vacant
Precise Plan IP
Industrial Shell
East Industrial Limited Industrial (MPA Application
Precise Plan(ILP) in Review to
rezone to RI)
West N/A N/A I-5 Freeway
PROJECT ANALYSIS
Land Use Compatibility
The establishment of a self-storage facility in the General Industrial Precise Plan (IP) zone is
permitted by right by the City of Chula Vista Municipal Code. The self-storage facility is an
appropriate land use at the proposed location and is compatible with surrounding development.
The Project is in proximity to industrial uses and will provide a service that meets the needs of the
community by providing additional capacity for self-storage. The buildings will be designed with
features that complement the architecture of the surrounding development.
Industrial Development Standards
Required for project Proposed for project
Zone: IP Storage uses are Permitted uses in an I zone as
Lot Size: 2. 81 acres or 122,485 feet stated in CVMC 19.46.020.
Height(CVMC 19.46.060): Within 200 feet Building 1: 39'8"at maximum height(3 stories
to Residential zone (MHP), cannot exceed max)
three stories or 50 feet in height. Building 2 and 3: 19' at maximum height(1 story).
Setbacks (CVMC 19.46.070):
Front Yard 25 feet Front Yard 26 feet 9 inches
Side Yard (Interior) 0 feet Side Yard (Int.) 2 feet
Side Yard (Exterior) 15 feet Side Yard (Ext.) varies, (15'to 89'8')
Rear Yard 0 feet Rear Yard Varies (13'6"to 17'1")
Maximum Lot Coverage: N/A Lot Coverage: 48. 6%
Maximum FAR: N/A FAR: 1.17
Parkin CVMC 19.62.050 :
Planning Commission
DR19-0001
September 25,2019
Page -4-
Storage
142,121 sf total self-storage area
1 space per 1,000 sq. ft. 36
Office Component: king Analysis dated 11-7-18 by LSA
1 space per 300 sq. ft. (1,488 sf total) 5
T Total arking spaces provided=25
Total parking spaces required 41
*The parking requirements noted apply to storage facilities in general and present the closest nominal standards in policy
regulations to what is being proposed.However,as has been used with other self-storage facilities in the past,a provision contained
within the Chula Vista Municipal Code Off-Street Parking Regulations (CVMC 19.62.050) indicates that for those uses not
specifically mentioned in the Municipal Code,the approving authority may apply a ratio based on a similar existing use.
Site Plan Elements
The Project Site Plan provides detail on parking and loading(located between the buildings so that
it is not visible from the street), circulation, landscape,trash and recycling(on the north side of the
building), as well as pedestrian access from Industrial Boulevard. Connections to and through the
site are also illustrated on the Site Plan and show the path for vehicular movement throughout the
property. The Project complies with the following design guidelines (as shown in Italic Font)
within the Palomar Gateway District Specific Plan:
Building Siting
The Chula Vista Self-Storage Project serves a need in Chula Vista and in the surrounding
community and provides convenient public access and visitor parking. The Project is a positive
asset for the community and incorporates a modern and streamlined design consistent with the
Chula Vista Design Guidelines for industrial development. The Project enhances the character of
the adjoining developments, while at the same time providing a consistent scale with the
surrounding development. The Project provides a functional and attractive configuration of
buildings, which are placed along the street frontage and parking is tucked behind the buildings so
that it is not visible from the street. The building coverage along the frontage, as well as the
landscaping along the exterior, provides an aesthetically pleasing view from the street and within
the site.
• Placement of structures should consider the existing built context of the industrial area,
the location of incompatible land uses, the location of major traffic generators as well as
an analysis of a site's characteristics and particular influences.
• A variety of building and parking setbacks should be provided in order to create diversity
and avoid long monotonous building facades.
Parking,Access and Circulation
The City of Chula Vista Off-Street Parking Regulations do not include specific parking
requirements for a self-storage use; therefore, the Applicant has prepared a Parking Analysis,
prepared by LSA, demonstrating that the proposed 25 parking spaces are appropriate given parking
requirements in other local jurisdictions and national parking rates provided by the Institute of
Planning Commission
DR19-0001
September 25,2019
Page -5-
Transportation Engineers (ITE) Parking Generation Manual 4 1 Edition. Additionally, two other
Self-Storage projects were recently approved by the City of Chula Vista (one in the Eastlake
Business Park and the other in Otay Ranch Village 3) and applied similar parking provisions.
Based on the parking assessment provided on November 7, 2018, the 25 parking spaces are within
the range of demand expected for the proposed Self-Storage facility and will be enough to
accommodate the peak parking demand.
Site access and internal circulation promote safety, efficiency and convenience. Conflicts between
vehicles and pedestrians have been minimized by locating the pedestrian access and building entry
close to the public sidewalk. The primary driveway is located just north of Moss Street. Parking is
provided on the east side of the primary storage building (Building 1) and is screened from
Industrial Boulevard by Building 2, Building 3/Office Building, as well as with landscaping along
the street edge.
The Caltrans right of way, and chain link fence located at the rear of the property along the I-5
freeway will remain undisturbed. A wrought iron security gate will be placed at the front of the
property, behind the front setback, by the entrance along Industrial Boulevard. The gate will serve
to separate the public parking spaces by the office area, and the secured parking spaces within the
site by the storage units.
• The main elements of sound industrial site design include: controlled site access; service
areas located at the sides and rear of buildings; convenient access, visitor parking and on-
site circulation; screening of outdoor storage, work areas and equipment; emphasis on the
main building entry and landscaping, and; landscaping and open space.
• Locate structures and on-site circulation systems to minimize pedestrian/vehicle conflicts.
Link structures to the public sidewalk where possible with walkways, textured paving,
landscaping, and trellises.
• The parking lot and vehicles should not be the dominant visual elements of the site. Large
expansive paved areas located between the street and the building are to be avoided in
favor of smaller multiple lots separated by landscaping and buildings. Introduce
decorative paving and canopy trees to add visual interest.
Building Design
As indicated above, setbacks for the buildings meet or exceed the requirements in the Chula Vista
Municipal Code Development Standards. Appropriate setbacks and proper screening help protect
nearby uses from noise, light intrusion, truck traffic and other objectionable influences incidental
to self-storage uses. Additionally, the placement of the buildings provides a strong street presence
as the buildings are configured along the street frontage, where the storage units are only exposed
from the interior of the lot. Parking is tucked behind the buildings and not visible from the street.
The office portion of Building 3 is accessible to any member from the public, while the storage
facilities are gated off and entry is granted with an access code. There is no maximum lot coverage
or floor area ratio in accordance with the Chula Vista Municipal Code Development Standards;
Planning Commission
DR19-0001
September 25,2019
Page -6-
however, the project proposes a total lot coverage of 48.6 percent, along with a FAR of 1.17.
There is no particular architectural style required for industrial structures. However, high quality,
innovative and imaginative architecture is encouraged. The Chula Vista Self-Storage Project has
a streamlined, modern industrial design, incorporating a plaster facade with metal elements, such
as ribbed metal panels, and metal cornices. Colors and materials are light grey with silver and red
accents. Wall planes are staggered to create visual relief, and the roof lines are heightened at
various points throughout the buildings to create visual interest. Tower elements are also utilized
to break up the building massing. All wall surfaces visible to the public are architecturally
enhanced and the buildings have offsets and architectural details, consistent with the Chula Vista
Design Manual.
• Heights and setbacks within the same building should be varied, and wall planes should
be staggered both horizontally and vertically in order to create pockets of light and
shadow and provide visual relief from monotonous, uninterrupted expanses of wall.
Large, unrelieved expanses of wall can also encourage graffiti (CVMC 9.20.055).
• There is no particular architectural "style"proposed for industrial structures. High
quality, innovative and imaginative architecture is encouraged. The focus is expected to
be on the development of a high-quality industrial environment. The architecture should
consider compatibility with surrounding character, including harmonious building style,
form, size, color, material and roofline. In developed areas, new project should meet or
exceed the standards of quality which have been set by surrounding development.
Landscape
The landscape design features drought tolerant shrubs and screening trees that complement the
landscaping along the edges of the project site. The landscape plans comply with the City's Shade
Tree Policy 576-19 and the City's Landscape Water Conservation Ordinance (Chula Vista
Municipal Code Ch. 20.12). Landscape is used to define the entrances to the buildings and to the
parking lot, and along all the edges of the site to blend the Project into its surroundings and soften
the built environment, as well as to screen incompatible or unattractive uses.
• For industrial uses, landscaping should be used to define areas by helping to focus on
entrances to buildings,parking lots, loading areas, defining the edges of various land-uses,
providing transition between neighboring properties (buffering) and providing screening
for parking, outdoor storage, loading, and equipment areas.
Project Operation Details
Access hours will be Monday through Friday from 9:00am to 6:00pm and Saturdays and Sundays
from 9:00am to 5:00pm for the office, and Monday through Friday from 7:00am to 9:00pm and
Saturdays and Sundays from 7:00am to 7:00pm for the storage units.
Compatibility
The Project is compatible with adjacent land uses and is a permitted use in the General Industrial
Precise Plan Zone,in accordance with Chula Vista Municipal Code Section 19.46.020, Chula Vista
Planning Commission
DR19-0001
September 25,2019
Page -7-
General Plan and Chula Vista Design Manual. The property is situated in such a way that the I-5
Freeway, freeway off-ramp, and Industrial Boulevard create a physical buffer from the adjacent
parcels. The only parcel directly connected to the Project site is also designated industrial and is
currently vacant.
CONCLUSION
The proposed Chula Vista Self-Storage Project has been prepared pursuant to the Chula Vista
Municipal Code, and Chula Vista Design Guidelines. Self-storage is a permitted use in the General
Industrial Precise Plan Zone, and the Project complies with the relevant policies and guidelines for
development within the Chula Vista Municipal Code. Therefore, staff recommends the Planning
Commission approve Design Review Permit, DR19-0001, subject to the conditions listed in the
attached Resolution.
DECISION-MAKER CONFLICTS
Staff has reviewed the property holdings of the Planning Commission members and has found no
property holdings within 1,000 feet of the boundaries of the property which is the subject of this
action. Consequently, this item does not present a disqualifying real property-related financial
conflict of interest under California Code of Regulations Title 2, section 18702.2(a)(7) or (8), for
purposes of the Political Reform Act(Cal. Gov't Code §87100, et seq.).
Staff is not independently aware, and has not been informed by any [Insert appropriate Legislative
Body name] member, of any other fact that may constitute a basis for a decision-maker conflict of
interest in this matter.
FISCAL IMPACT
All application fees and processing costs are borne by the Applicant, resulting in no net fiscal
impact to the General Fund or the Development Services Fund.
Attachments
1. Locator Map
2. Planning Commission Resolution DR19-0001
Enclosure: Site Plan, Elevations, Landscaping Plan, Parking Analysis, Phase I Environmental
Site Assessment(Included on USB flash drive)