SEWER SYSTEM ANALYSIS
FOR THE
OTAY RANCH PLANNING AREA 12
EAST RESIDENTIAL SITE
CITY OF CHULA VISTA
February 25, 2019
SEWER SYSTEM ANALYSIS
FOR THE
OTAY RANCH PLANNING AREA 12
EAST RESIDENTIAL SITE
CITY OF CHULA VISTA
February 25, 2019
Prepared by:
Dexter Wilson Engineering, Inc.
2234 Faraday Avenue
Carlsbad, CA 92008
760-438-4422
Job No. 605-837
DEXTER WILSON ENGINEERING, INC.
February 25, 2019
Baldwin & Sons
610 W. Ash Street, Suite 1500
San Diego, CA 92101
Attention: Nick Lee, Vice President
DEXTER S. WILSON , P.E .
ANDREW M. OVEN, P.E.
STEPHEN M. NIELSEN, P.E.
NATALIE J. FRASCHETTI, P.E.
STEVEN J. HENDERSON, P.E.
605-837
Subject: Sewer System Analysis for the Otay Ranch Planning Area 12 East
Residential Site Project
PROJECT DESCRIPTION
The Otay Ranch Planning Area 12 East Residential Site project is located in the City of
Chula Vista. The project is located in the northwest portion of Otay Ranch Planning Area
12. The project is located along the east side of Town Center Drive, along the south side of
Olympic Parkway. Figure 1 provides a location map for the project site.
The approximately 10.4 acre site is currently undeveloped. The project proposes to develop
578 multi-family residential dwelling units in two buildings. Building "A" proposes 237
units as well as 15,000 square feet of retail commercial space. Building "B" proposes 341
units. The project site has elevations that range from 617 feet to 636 feet. The purpose of
this report is to present an analysis of the private onsite sewer system that will provide
service to the project and to evaluate the impact of the project on the public sewer system in
the area.
2234 FARADAY AVENUE • CARLSBAD , CA 92008 • (760) 438-4422 • FAX (760) 438-0173
CONSULTING ENG I NEERS
(760) 438-4422
FIGURE 1
VICINllY MAP
PLANNING AREA 12 EAST RESIDENTIAL
Nick Lee
February 25, 2019
PRIVATE SEWER SYSTEM ANALYSIS
Sewer System Overview
All onsite sewer lines for the project site will be private sewer lines. The project will have
two connections to the 8-inch public sewer line in Town Center Drive. One connection will
be made to an existing stub. The backbone 8-inch private sewer lines that convey flow from
the building sewer laterals were designed to the City of Chula Vista Engineering
Department public standards. Figure 2 provides the proposed sewer system for the project.
Design Criteria
The criteria for evaluating sewer line sizing is provided as follows:
Private Sewer Lines Designed to Engineering Department Standards. According to
the Sewer Design Criteria provided in the City of Chula Vista Subdivision Manual, Section
3-300, the minimum size for sewer mains is 8-inch diameter. The minimum required
velocity is 2.0 feet per second (fps). Where a velocity of 2.0 fps cannot be achieved, a
minimum pipe slope of 1.0 percent is recommended. Additionally, while conveying peak
flow, pipes should not flow more than half full. A Manning's Equation "n" value of 0.012
was used for the calculations.
Estimated Sewage Flows
The project consists of 578 multi-family residential units and retail commercial space. The
City of Chula Vista 2014 Wastewater Master Plan indicates that the sewage generation
factor for multi-family residential units is 182 gpd/DU and for commercial space is 80 gpd
per 1,000 square feet.
DEXTER WILSON ENGINEERING, INC. PAGE3
Nick Lee
February 25, 2019
Peak flow was determined by using the peaking factor curve CVD-SW0l found on the City
of Chula Vista Development Services website. The peaking factor is based on the total
estimated population for the project. Equivalent population was determined based on a
factor of 80 gpd/capita. Using the peaking factor curve gives a peaking factor of 2.42. Table
1 provides a summary of the total estimated sewage flow from the PA 12 East Residential
project.
TABLE 1
ESTIMATED SEWAGE FLOW
Proposed Sewage Average
Development Quantity Generation Sewage
Factor Flow, gpd
Multi-family 578 units 182 gpd/unit 105,196
Commercial 15,000 sf 80 gpd/1,000 1,200 sf
Total 106,396
Equivalent Population 1,330
Peak Factor 2.42
Peak Flow 257,478
Analysis of Private Sewer Designed to Engineering Department Standards
Hydraulic calculations were performed for the 8-inch backbone private sewer lines designed
according to the Engineering Department public standards. The calculations are presented
in Appendix A and verify that the recommended pipe sizes are adequate . The lines that
convey flow from the project will flow less than 50 percent full by depth during peak flows
as required by the City Engineering Department Standards.
DEXTER WILSON ENGINEERING, INC. PAGE4
Nick Lee
February 25, 2019
PUBLIC SEWER SYSTEM ANALYSIS
Flows from the project will connect to an existing 8-inch public sewer line in Town Center
Drive. This line conveys flow north to the Poggi Canyon Interceptor in Olympic Parkway.
Capacity in the Poggi Interceptor was analyzed as part of the SPA Amendment for the
project and, as a result, this study is focused on evaluating capacity in the 8-inch line in
Town Center Drive. The 8-inch sewer line in Town Center Drive was constructed at a slope
of 2.0 percent. This sewer was stubbed out to serve the Planning Area 12 East Residential
site. Appendix B provides the calculation for this existing sewer line with the addition of
project flows and confirms that it has capacity to serve the project.
Sewer System Conclusion and Recommendations
The following recommendations and conclusions are presented based on the sewer system
analysis for the Planning Area 12 East Residential project.
1. All onsite sewer lines will be private sewer lines. The onsite backbone 8-inch sewer
lines are designed to the City of Chula Vista Engineering Department Public
Standards.
2. Flows from the project will be connected to an existing 8-inch public line in Town
Center Drive at two locations. One connection will be made to an existing stub.
3. The existing 8-inch public sewer line in Town Center Drive was confirmed to have
adequate capacity to serve the project.
DEXTER WILSON ENGINEERING, INC. PAGES
Nick Lee
February 25, 2019
Thank you for the opportunity to assist you with the sewer system planning for this project.
If you have any questions regarding the information presented in this report, please do not
hesitate to call.
Dexter Wilson Engineering, Inc.
Stephen M. Nielsen, P.E.
SMN:pjs
Attachments
DEXTER WILSON ENGINEERING, INC. PAGE6
~
N
I
BUILDING A
CONNECT TO EXISTIN
SEWER STUB
~------I I ----8,)t
~
... ,e,£> ~
£,>J\\J)\\, ~ -----
::::---
---=::::::..____ _ -------------1:EGEN~R ~ECT BOUNDARY
- - - -EXISTl~G PUBLIC SEWER
-----PROPo l D PRIVATE SEWER
\
XTER WILSON ENGINEERING , INC .
DE CO N S U L TI NG ENG IN EE R S
(7 60) 4 38-44 22
--....... ---I
---l 1--
FIGURE 2
PROPOSED SEWER
SYSTEM
PLANNING AREA 12 EAST RESIDENTIAL
APPENDIX A
HYDRAULIC ANALYSIS OF PRIVATE SEWER LINE
PA -12 East Residential Site
Backbone Sewer Line
8-lnch Private Sewer Line Calculations
8" Sewer Line Capacity at 0.5% Slope
Utu11 = (0.463/n)*(D)813 *(S)112
Where Utull = full pipe capacity, cfs
n = Manning's coefficient= 0.012
D = Pipe diameter, ft.
S = Pipe slope, ft/ft
So Utull = (0.463/0.012)*(8/12)813 *(0.005)112
Utull = 0.925 cfs = 0.60 mgd
Peak Flow
URes = 341 units x 182 gpd/unit = 62,062 gpd (worst case = all of Building B)
Total Oavg = 62,062 gpd
Peak Factor= 2.50
(lpk = 155,155 gpd
(lpk = 0.155 mgd
Determine d/O
Qpk/Otull = 0.155/0.60 = 0.26
Per attached graph, d/D = 0.35 < 0.50 OK
M
PROFESSIONAL ENGINEERING REGISTRATION PROGRAM
P.O. Box 91 i, San Carlos, CA 94070
Figure 5.20
Circular Channel Ratios
Page: 5-27
Experiments have shown that n varies slightly with depth. This figure gives velocity and flow rate ratios for varying n (solid line) and constant n (broken line) assumptions ..
---------,,. , --~ / .__
/ ' ........ 1,,,. ---"~ ... , ....
' ....
I ', ... ,~ -~ .... ~ ' ..... '
"' ........
" "' .
\ ' ~ I\ "-
\ ,
" \ ~ r,.._ \
\ \ . '"' \
\ \ ·-'
\ \
\ \
\ \
' ~ \
\
\
\ ' \ \
\ \
}.
I/
I\
.,
e
"' ~ u ..
'c
,
C: -----:--....---__....
L---...-----I . ---
' ' .' .
\ ' ' ' \,
\
\ :,. ' ... u
0 ' oi J( > '· N \
\
' "". \
\
' "' ~
\
\
' \
'
\ ' \
\
\
i\ \
\ \
\
\ \.
'"' \
\ ' \
\
"-
..
\
\
\
\
\
\
\
' ' ·,
~
..
\
\
'
\ .
' ~ \
\ \
\
I\ \
\
\ ' ' \
\ \
\
\ I'
\
' \
\
\ -i'---...., \
"'~ \ ' ..... ',
-......:: ~ _1 ---'
... ...
0. ...
~
I!!
Lq
0 0. O"!
0
co
c:i
,...
c:i
(0
ci SI;
0
l.rl , I'? ,..,. .
• 0
N
0 -0 -0
Ratio of Flow Depth to Diameter (d/D}
:,
0 g
-c
C
"'
.E.
~
~
APPENDIXB
HYDRAULIC ANALYSIS OF PUBLIC SEWER LINE
PA -12 East Residential Site
Town Center Drive
8-lnch Public Sewer Line Calculations
8" Sewer Line Capacity at 2 .0% Slope
Otull = {0.463/n)*{D)813 *{S)112
Where Otu11 = full pipe capacity, cfs
n = Manning's coefficient= 0.012
D = Pipe diameter, ft.
S = Pipe slope, ft/ft
So Otull = {0.463/0.012)*{8/12)813 *{0.02)112
Otull = 1.85 cfs = 1.20 mgd
Peak Flow
0Res = 578 units x 182 gpd/unit = 105,196 gpd
Ocom = 15,000 SF x 0.08 gpd/SF = 1,200 gpd
Total Oavg = 106,396 gpd
Peak Factor= 2.42
Qpk = 257,478 gpd
Qpk = 0.257 mgd
Determine d/D
Qpk/Otull = 0.257 /1.20 = 0.21
Per attached graph, d/D = 0.31 < 0.50 OK
M
3 ...
C .-]: ,-
PROFESSIONAL ENGINEERING REGISTRATION PROGRAM
P.O. Box 91 i, San Carlos, CA 94070
Figure 5,20
Circular Channel Ratios
Page: 5-27
Experiments have shown that n varies slightly with depth. This figure gives velocity and flow rate ratios for varying n (solid line) and constant n (broken line) assumptions ..
------.... --,,.. -,-.. .......... _ .,,. ,,,
I ' ..... 1,,, --.... .... ',. ..... ,, ....
I '
V -' ~ ~ ... ....
'
""
. --........
"' I'\
' '\ \. "" I'\ ·. :-....
\ .. " \. r"-. " \
\ .
'~ r,,
\
\ \ ..
'
\ \
\ \
\ \
~
\ \
\
\
\ \ \.
\ \
\
)-
ll
I\
.,
C, ... ..
.i:;
(J ..
~
/
" " .''
\ ' ' ' V,
' ' > ' ... u
0 ' j ,(
'· N '
"'· "" ~
\
\
\
'
\ ' \
\
' I\ \
\ \
\
\ '\ ~..,.
\
\
\
\
\
' \
\
\
\
\ ' \
\
\ T
\
\
i\
\
..
\
\
\
\
\
\
I\
\
\
' \
\
\
\'
\
I-
\
... ...
q ...
"":
tq
Lt?
3
0 g
-0
C: ..
"5 > }
rJ
\ \ N • ·c "' \
\ \ ' \
C: ~ " -~ \ ------' ·, ...... ---~ " "\ --' ---..... "' .,...,.-------' ~ \~ __.,.. I ----i
0 . ' .. 00
ci
....
ci tq Lt? '<I; -~ 0 0 0 M O
..
ci
Ratio of Flow Depth to Diameter (d/D-1 O