Loading...
HomeMy WebLinkAboutSewer Capacity Analysis SEWER CAPACITY ANALYSIS THE ELMS & THE IVY DEVELOPMENT SUBMITTAL DATE: AUGUST 7, 2013 2013 LATITUDE 33 PLANNING & ENGINEERING 5355 MIRA SORRENTO PLACE, SUITE 650 SAN DIEGO, CA 92121 JOB NUMBER :1114.00 SEWER CAPACITY ANALYSIS BONITA GLEN DEVELOPMENT ORIGINAL DATE: 04/05/2018 2018 LATITUDE 33 PLANNING & ENGINEERING 9968 HIBERT STREET, SECOND FLOOR SAN DIEGO, CA 92131 JOB NUMBER :1522.00 PRELIMINARY SEWER STUDY FOR BONITA GLEN ORIGINAL DATE: Prepared Under the Responsible Charge of: Giovanni Posillico RCE 66332 EXP: 06-2018 Latitude 33 Planning and Engineering 9968 Hibert Street, Second Floor San Diego, CA 92131 TABLE OF CONTENTS INDEX PAGE Introduction 1 Project Description 1 Vicinity Map 2 Design Criteria 2 Calculations and Results 3 Conclusion 3 APPENDICES Appendix A Sewer Study Calcualations Appendix B Sewer Study Exhibit INTRODUCTION This preliminary sewer study addresses the proposed development of Bonita Glen. The purpose of this  preliminary sewer study is to determine the impact on the existing 8” sewer main downstream from the  proposed development to its point of connection to the existing 8” sewer in Bonita Road.  PROJECT DESCRIPTION The proposed project is located northeast of the Pont Bonita Apartments and Townhomes and  north of Bonita Glen Dr.     EXISTING CONDITIONS The existing site is vacant land with a jurisdictional waters in the center flowing to the west on the site. PROPOSED CONDITIONS Silvergate Development, LC, is seeking approval to construct 130 townhome/stacked flat units  with associated structure/surface parking. The proposed development will be served by  connecting to existing public infrastructure (storm drain, water and sewer) within the adjacent  street (Bonita Glen Drive).  Refer to the proposed site plan below.  The public sewer system will be analyzed per City of Chula Vista Sewer Guidelines.   DESIGN CRITERIA The public sewer main systems have been analyzed per the City of Chula Vista Sewer Design Guide,  2012. The following assumptions were used in the calculations:    1) Average flows are based on 80 gallons per day per equivalent population per the Sewer Design  Guide Subsection 3‐301.1.    2) Population calculated based on residential (R1) zoning and land use with a density of 4 dwelling  units per acre and 3.3 persons per dwelling unit per Sewer Design Guide subsection 3‐301.     3) Existing flows were calculated using the listed peaking factors in CVD‐SW01.    4) For existing sewer systems reference drawings:     5) The Manning’s roughness coefficient (n) of 0.012 was used for open channel flow calculations for  PVC and (n) of 0.013 for exiting V.C. pipe per Sewer Design Guide subsection 3‐301.2.         CALCULATIONS AND RESULTS Flow calculations were based off of the following equation: K=Qn / d^(8/3) s^(1/2) Where, K=Kings Handbook Table 7-14 Q= Flow (cfs) n=Manning’s coefficient of roughness d=Depth of Flow s=% Slope CALCULATED SEWER FLOW RATE RESULTS The existing conditions contribute a sewer flow rate of 29,180 gallons per day (0.045cfs), see Table 3. The proposed development contributes a sewer flow rate of 43,180 gallons per day (0.067cfs) see Table 4. CONCLUSION In accordance with current zoning and field observations and based off the calculations found in Tables 3 and 4, Bonita Glen is contributing an additional 0.02 CFS to the existing system for an increase of 0.9% of the total flow for the study area. The existing sewer system is flowing less than half full, therefore the additional flows generated by the proposed development will be serviced by an existing sewer system with adequate capacity per City standards. The proposed development will not increase the existing service above the anticipated flows per the City of Chula Vista Wastewater Master Plan. APPENDIX A Sewer Study Calculations TABLE 3 JOB NO. 1522.00 PREPARED BY: J.L.DATE: 2015.08.19 PEAK DESIGN FLOW LINE DESIGN dn(FT) FROM TO POP. SERVED PEAK/AVG SIZE SLOPE n= **dn/D Rh VELOCITY Comments LINE MH MH INLINE TOTAL RATIO M.G.D. (calculated) M.G.D. (metered) CFS (calculated) CFS (metered) (INCHES) (%) 0.013 (ft) (fps) (EXISTING) 145.9 145.9 2.50 0.029 n/a 0.045 n/a 8 3.00 0.07 0.10 0.04 2.4 A-3 TABLE 4 JOB NO. 1522.00 PREPARED BY: M.M. DATE: 2017.11.28 PEAK DESIGN FLOW LINE DESIGN dn(FT) FROM TO POP. SERVED PEAK/AVG SIZE SLOPE n= **dn/D Rh VELOCITY Comments LINE MH MH INLINE TOTAL RATIO M.G.D. M.G.D. (metered) CFS CFS (metered) (INCHES) (%) 0.013 (ft) (fps) (PROPOSED) 215.9 215.9 2.50 0.043 n/a 0.067 n/a 8 3.00 0.08 0.12 0.05 2.7 A-4 APPENDIX B Sewer Study Exhibit